TODAY :
SEE ALSO :
TYPACT - TPy2…4B
Single-phase four quadrant armature converters
 

* Supply: 1 x 415V
* Nominal currents: 15...42A
* Protection degree: IP00


Product Certifications:


      

The power section consists of a non-parallel and double Graetz bridge. For the armature reaction use the TVO-1 transducers and if the ramp circuit is needed, use the AGy option card.

::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: DOWNLOADS ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

Brochure
- TPy2 Regenerative DC Drives
- TPy2 Non-Regenerative DC Drives
- Drive Selection Guide


Catalog
- Typact Series Analog DC Drives General Catalog
- Extract from "General Catalogue: 2000/2001 Drives & Systems"

Instruction Manual
- TYPACT TPy2…4 Instruction Manual (USA Version)

Other Manuals
- TPy2-415-280-15_42-4B_AWA_g, Installation manual
- EMC, Electromagnetic compatibility
- TPy2-415-280-15..42-4B, Instruction manual

Installation Handbook
- Power supply board, ALy (P)
- Ramp function generator, AGy card

   
   
 
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: NOTES ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
 
 

The adjustment to other voltages, frequencies and tacho reaction is obtained via internal switches. TYPACT - TPy2...4B converters make it possible to mount up to three “y” option cards on the rear side of the regulation card with an internal connection to the converter via a flat cable and a FA… connector.              . . . .

 
 
::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: FEATURES :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
 
 
  • Field power supply: Internal field rectifier
  • Internal reference: +10V
  • Reaction: Max. 300V tachogenerator, adjustment via resistors
  • Armature with RxI compensation, Internal connection
  • Enabling +15...24V:
         - regulation (+ramp)
         - ramp
         - reference
         - direct enabling via PLC
  • Speed threshold signal (with contact and +24V): 0,5...3,5% nmax
  • Connection for external indicators of armature current and speed, converter
  •    internal tuning.
  • :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: FUNCTIONS ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
  • Current adaptive
  • Possibility for: external current limit, current regulation, regulation and power
         simultaneous setting, power and regulation separate power supply
  • Possibility for an internal mounting of the “…y” option cards (max 3)
  • LED signaling the functioning conditions
  • Internal switches and adjustments via dip-switches.
  • ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: OPTIONS :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
  • Armature with RxI compensation (External connection, by using TVO-1 card)
  • Ramp circuit: use AGy card
  •  

    HOMEPAGE : COMPANY : PRODUCTS : SERVICES : APPLICATIONS : CONTACT US