Field-oriented vector inverter, from 0,75 to 630kW
 


* Power supply 3ph:
  230V –15%…480V +10% 50/60Hz ±5%
  575V ±10% 50/60Hz ±5%
* Rectified voltage supply version up to 480V +10% 50/60Hz
   ±5%
* Motor ratings from 0.75kW (1 Hp) to 630kW (700Hp)


Product Certifications:



The SIEIDrive AVy series represents an innovative field-oriented vector inverter concept, capable of incorporating the needs of OEMs, systems integrators and panel builders to make them more innovative and competitive in international markets.

::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: DOWNLOADS ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

Brochure
- AVy, … life is performance
- Drive Selection Guide

Catalog
- SIEIDrive AVy, 2007 Catalog

- SIEIDrive AVy, 2007 Catalog - Addendum 690V versions
- Accessories 2008

User Manual
- EXP-SFTy, Safe stand-still function
- Modbus, Protocol
- EXP-ENDAT-AVy, Absolute Encoder with EndDat Protocol
- EXP-E, 1 optocoupled encoder data repeater TTL (@5V) and HTL (@15….24V)...
- SBI-PDP-33, Profibus-DP interface card
- BUy, Braking Unit
- Easy Drive, Configuration sw
- E-ABS, Absolute encoder interface
- BU32, Braking Unit
- AVy -KTR, Keypad remote mounting kit
- RV33-4, Addendum for AVy 1.X
- EMC, Electromagnetic compatibility
- AVy - Vector AC Drives V2 series (400Vac - 575Vac Class), Instruction manual
- AVy 250...630 kW, Addendum
- AVy, Quick start
- AVy, Function description and parameters list
- AVy 6750...111200 - 690V, Addendum
- APC100y-APC200d, Application Board
- ARS-485, Supply interface
- ENC-ADPT, Encoder connection adapter
- EXP-D14A4F, Analog I/O Expansion
- EXP-D16, Digital I/O Expansion
- EXP-D20A6, Analog I/O Expansion
- EXP-D8R4, Digital I/O Expansion
- EXP-D8-120, I/O interface card
- EXP-F2E, Encoder Two Channels
- EXP-FI, 1 digital encoder input with zero channel and Encoder qualifier input
- EXP-FIH, 1 optocoupled digital encoder input 15V/24V
- EXP-FIO, 1 digital encoder input & Encoder qualifier input, 1 encoder data repeater
- EXP-FO, 1 encoder data repeater TTL (@5V) with zero channel
- EXP-RES, Resolver interface
- H-IP54, Heatsink IP54 kit option from 1007 up to 3150
- PCI485, interface
- PosMono , One axis pos. for DGFC
- SBI-COP33, CanOpen
- SBI-DN33, DeviceNet
- SLINK3, Serial Protocol
- Win+Drive 4&5, Instruction manual
- PCI-COM, interface

Driver
- GSD File, SBI-PDP-33

Configuration Tools
- 1S9C39_AVy_EASY DRIVE (32.29Mb zip file)

   
   
 
:::::::::::::::::::::::::::::::::::::::::::::::::::: THE AVy ADVANTAGE ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
 
 

Thanks to its advanced functions, high level of precision and ultimate performance, AVy is cutting edge for any application where maximum motor performance and regulating sophisticated control architectures are an absolute must. AVy is extremely adaptable to every technical requirement of state-of-the-art processes and control systems, not to mention that its extensive range and a series of specialized configurations successfully guarantee virtually universal automation solutions.

 
 
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: VERSIONS ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
 
 
Standard versions (AVy & AVy…-4A)
- Power supply 3ph 230V –15%…480V +10% 50/60Hz ±5%
- Motor ratings from 0,75kW (0,75Hp) to 315kW (450Hp)
Standard versions (AVy…-5)
- Power supply 3ph: 575V ±10% 50/60Hz ±5%
- Motor ratings from 2Hp to 200Hp
Cabinet versions (AVy Cabinet)
- Power supply 3ph: 400V –15%…480V +10% 50/60Hz ±5%
- Motor ratings from 250kW (300Hp) to 630kW (700Hp)
- Standard protection degree IP23 (higher on request)
DC bus power supply versions (AVy...DC)
-Rectified voltage supply up to 480V +10% 50/60Hz ±5%
- Motor ratings from 22kW (25Hp) to 630kW (700Hp)
Versions with external heat sink assembly (AVy…EH)
- Power supply 3ph: 230V –15%…480V +10% 50/60Hz ±5%
- Motor ratings from 22kW (25Hp) to 55kW (60Hp)
Liquid cooling versions (AVy…WH)
- Power supply 3ph: 230V –15%…480V +10% 50/60Hz ±5%
- Motor ratings from 11kW (15Hp) to 132kW (150Hp)

:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: FEATURES ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
  • Regulation control modes:
         - Flux Vector closed-loop with feedback
         - Flux Vector open-loop without feedback (Sensorless)
  • Output frequency 400Hz
  • Integrated LIaking module up to 15kW, integrated as option up to 55kW
  • Alphanumeric programming keypad
  • Digital I/O commands in PNP and/or NPN logic
  • 3 differential analog inputs ± 10V
  • 8 digital inputs
  • 4 digital outputs (2 opto-coupled and 2 relays)
  • Programmable Overload up to 200% (IEC 146-1-1 Class 1 and Class 2)
  • RS485 serial port (Modbus RTU protocol)
  • Interfacing with the more common field bus interfaces: ProfiBus, CANopen,
         DeviceNet
  • IP20 protection degree as standard (drive predisposition for mounting in
         IP54 with external heatsink)
  • ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: FUNCTIONS :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
  • Programming multilanguages keypad KBG-LCD-2 (IT-ENG-GERM)
  • Programming multilanguages keypad KBG-LCD-A2 (ENG-FR-SP) for
         AGy…-4 version
  • I/O expansion card EXP-D6A1R1-AGy
  • 120Vac Digital input interface EXP-D8-120
  • Encoder feed-back interface QUIX-ENC
  • ProfiBus interface card SBI-PDP-AGy
  • Memory key PRG-KEY
  • Dedicated EMC filters (in compliance with CEE - EN61800-3 european directive)
  • LIaking resistors (standardised for the whole line)
  • Input and Output choke (standardised for the whole line)
  • NEMA 1 type Kit
  • Programming remote keypad Kit
  • ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: OPTIONS:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
  • I/O expansion cards, configurable according to the customer's machine needs
  • Expansion cards for the management of auxiliary encoders (Incremental,
         Absolute, Resolver)
  • Field-bus interface cards on board or in “stand alone” configuration: ProfiBus,
         CANopen, DeviceNet
  • Programmable Application Card
  • Safety cards for the power output LIidge disabling (UNI IN 954-1 category 3)
  • Dedicated EMC filters (in compliance with CEE - EN61800-3/A11)
  • LIaking resistors (standardized for the whole line)
  • Input and Output chokes (standardized for the whole line)
  • NEMA 1 type kit
  • Remote keypad kit

  •  